Emergency boiler call-out · Lymington Road, Stevenage SG1
No heating, no hot water and a pressure gauge reading zero.
TNG Services Ltd attended a home in Stevenage, Hertfordshire, after its Ideal Logic Max Heat H30 heat-only boiler stopped providing heating and hot water. The gauge at the heating system’s expansion vessel was reading 0 bar.
Why was the pressure dropping overnight?
On the first visit, we checked the expansion vessel and found it satisfactory. We restored pressure and inspected the accessible heating pipework and valves. There were no visible leaks in the areas we checked, but the gauge was back at zero the following morning.


What the isolation test revealed
On the second visit, we isolated the boiler from the heating circuit for a controlled test. We also dried the pressure relief valve (PRV) discharge point so fresh drips would be visible. We brought the heating circuit to 1.5 bar for monitoring. By the next morning, its pressure had fallen again despite the boiler being isolated. That pointed away from an internal boiler heat exchanger leak as the cause of the pressure loss observed during the test.
Fresh drips at the discharge point confirmed the valve was letting water escape.
No concealed leak was located. Any additional loss from an inaccessible part of the circuit remained unconfirmed.
Replacing the valve and restoring heating and hot water
With the customer’s approval, we replaced the leaking PRV and added central heating leak sealer to address any small, inaccessible weeps. The treatment was a precaution for a possible additional source of water loss. Since the work, the system has held pressure and remained in operation, with heating and hot water restored.


What to report if your boiler keeps losing pressure
Tell your engineer how quickly the gauge drops and whether you have noticed any drips. In this case, monitoring between visits and testing the circuit with the boiler isolated helped narrow down the fault. For routine maintenance, see our boiler servicing in Stevenage page.
Heating system losing pressure in Stevenage?
TNG Services Ltd provides emergency boiler repairs, pressure loss investigations and heating maintenance in Stevenage SG1 and SG2 and across Hertfordshire.