Two leaks in existing pipework
After Cadent isolated the supply, TNG traced two leaks in old black iron pipework. The job also addressed separate wall-sleeving and bonding defects.
Read the Bushey investigation →TNG Services can discuss landlord gas safety checks for a property in Letchworth Garden City. Share the appliance list, current record and access details, and explain whether the request also includes boiler maintenance or an existing installation concern.
Share the property address, appliance list, previous record and access arrangements.
The relevant appliances and flues are assessed by an appropriately qualified Gas Safe registered engineer.
Keep the record, provide the tenant’s copy and arrange any necessary remedial work.
Showing the single result
Check that the address and appliance information on your records match the property you are arranging the visit for. If an appliance has changed, include the replacement details and available installation paperwork.
Accurate information avoids confusing a previous appliance record with the current setup. The inspection and documentation should relate to what is actually installed, not simply copy an earlier description.
These examples come from gas leak investigation and boiler service visits. They illustrate defects found during TNG’s work; they are not presented as completed landlord CP12 inspections.

After Cadent isolated the supply, TNG traced two leaks in old black iron pipework. The job also addressed separate wall-sleeving and bonding defects.
Read the Bushey investigation →
An inspection found incorrect flue fall, inadequate support and securing, and an unsleeved gas pipe wall entry. The installation was classified At Risk; the article documents the findings rather than completed repairs.
See the Stevenage findings →
The boiler operated with satisfactory combustion readings, but the visit identified a flue defect and gas-pressure concerns. Separate cylinder and visual electrical observations were also recorded.
Explore the Borehamwood inspection →Yes. Include the model and available installation paperwork, together with the previous gas safety record.
Send the property postcode in Letchworth Garden City, the gas appliance list, previous record and due date if known. Explain access arrangements and any existing faults or notices. Avoid unnecessary tenant personal information.
No. The record contains the completed check results. Read the findings and arrange any required remedial action; an unsafe appliance must not be used.
Landlord checks are required annually. Existing tenants need a copy of the record within 28 days; new tenants need it before moving in. Retain records for at least two years, with additional retention conditions when using early-check flexibility.
Read the main landlord gas safety and CP12 guide →Share the property details and the work requested. Coverage, access and the proposed appointment can then be confirmed.
Arrange a gas safety enquiry