Two leaks in existing pipework
After Cadent isolated the supply, TNG traced two leaks in old black iron pipework. The job also addressed separate wall-sleeving and bonding defects.
Read the Bushey investigation →TNG Services can discuss landlord gas safety checks and CP12 records for a Stevenage property. Include the appliances, previous record and any known installation concerns, so the requested visit is planned around the actual property.
Share the property address, appliance list, previous record and access arrangements.
The relevant appliances and flues are assessed by an appropriately qualified Gas Safe registered engineer.
Keep the record, provide the tenant’s copy and arrange any necessary remedial work.
Showing the single result
Our Stevenage At Risk case documented incorrect flue fall, missing support, unsecured flue joints and an unprotected gas pipe wall penetration. It describes inspection findings rather than claiming completed repairs.
The case is not presented as a landlord CP12 visit. It provides practical context for why known installation concerns should be included when arranging checks or further work.
These examples come from gas leak investigation and boiler service visits. They illustrate defects found during TNG’s work; they are not presented as completed landlord CP12 inspections.

After Cadent isolated the supply, TNG traced two leaks in old black iron pipework. The job also addressed separate wall-sleeving and bonding defects.
Read the Bushey investigation →
An inspection found incorrect flue fall, inadequate support and securing, and an unsleeved gas pipe wall entry. The installation was classified At Risk; the article documents the findings rather than completed repairs.
See the Stevenage findings →
The boiler operated with satisfactory combustion readings, but the visit identified a flue defect and gas-pressure concerns. Separate cylinder and visual electrical observations were also recorded.
Explore the Borehamwood inspection →No. It documents the defects found during the inspection and the need for remedial work.
Send the property postcode in Stevenage, the gas appliance list, previous record and due date if known. Explain access arrangements and any existing faults or notices. Avoid unnecessary tenant personal information.
No. The record contains the completed check results. Read the findings and arrange any required remedial action; an unsafe appliance must not be used.
Landlord checks are required annually. Existing tenants need a copy of the record within 28 days; new tenants need it before moving in. Retain records for at least two years, with additional retention conditions when using early-check flexibility.
Read the main landlord gas safety and CP12 guide →Share the property details and the work requested. Coverage, access and the proposed appointment can then be confirmed.
Arrange a gas safety enquiry